What was found
LEFT HYD ELEC DEMAND PUMP IN AUTO CAUSES PRESS AND SYS PRESS LTS TO ILLUMINATE. WORKS IN ON. DEFERRED LEFT HYD ELEC DEM AND PUMP AUTO FUNCTION IAW MEL. REPLACED K130 RELAY. LEFT HYD DEMAND PUMP OPERATES NORMAL IN AUTO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT HYD ELEC DEMAND PUMP IN AUTO CAUSES PRESS AND SYS PRESS LTS TO ILLUMINATE. WORKS IN ON. DEFERRED LEFT HYD ELEC DEM AND PUMP AUTO FUNCTION IAW MEL. REPLACED K130 RELAY. LEFT HYD DEMAND PUMP OPERATES NORMAL IN AUTO.