As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM HAS CORROSION AT STATION 1661 LBL 11 AND RBL 4. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA OF TOP CHORD AND FABRICATED REPLACEMENT BEAM AND 2 SUPPORT ANGLE AND 2 STRAPS IAW SRM. TREATED AND PRIMED ALL PARTS PER 757 SRM. INSTALLED REPAIR PER SRM AND TOP COATED PER SRM.