What was found
RIGHT PRSOV MSG DISPLAYED PRIOR TO DEPARTURE. ALSO RECEIVED STATUS MESSAGE R FAMV. BITE CHECK, ENG RUN NO HELP. PRSOV MANUALLY LOCKED CLSD. REPLACED PRSOVC. ALSO ACCOMPLISHED PNEU HEALTH CHECK. OPS CHECK NORMAL. LOCKED OUT R FAMV PER MEL 3611F. CHECKED WIRING TO FAMV FROM ASCPC TO DV36118, CHECKS GOOD 5VAC TO PINS 1 & 2 OF DV36118 CHECKS GOOD TOO. ACP'D PNEUMATIC HEALTH CHECK ON FAMV PER MM. HPFAC EXCEEDED UPPER LIM READING 48 PSI. HPFAC NEEDS TO BE REPLACED (PCN 646-9027). HPFAC REPLACED PER MM, OPS CHECK OKAY.