Service difficulty report · Module · Boeing 777222

Difficulty date
April 2, 2011
Submitted
April 6, 2011
Operation
Air carrier
Aircraft
N220UA
Make and model
Boeing 777222
Aircraft serial
30223
Aircraft time
41,014 hours, 5,100 cycles
Engine
Pwa PW40903
Part
Module
Part number
ELM80561
Part serial
E36213
Condition
Faulty
Location
Electrical Sys
Stage of operation
IN
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

"ELEC STANDBY SYS" STATUS MSG. MSG'S 24-13106 AND 24-13143 LATCHED. REPLACED ELMS 310 DCS CARD M2440612 PER MM. MSGS CLEARED. AFTER SWAPPING IN M24406A3 AND M24406A12 CARDS, ELMS P310 PANEL, CPCS REMOTE SENSOR AND AIR-GROUND R STATUS MESSAGES ARE NOW PRESENT. PERFORMED AIR GROUND RESET TEST ON MAT MSG'S CLEARED. REPLACED LEFT AIMS I-O MODULE M004 (P/N S243W001-1201 SERIAL# 141). FOUND ELMSP310 NO SOFTWARE. RPL A1,A2,A3 CARDS AND LOADED B CH. UNABLE TO LOAD A CH. TRIED BOTH L&R AIMS CABINET A,TRIED 3 TIMES, NO HELP. SOFTWARE OLIPC 46-00-00-042B, CARDS OLIPC 24-09-01-029B. OLD MAINT MSG 24-18803 GONE NOW SOFTWARE INCOMPATIBLE. IN ELMS P310, A1 PSU CH A & & A3 ARINC 629 CARD & REINSTALLED A2 CPU CH A CARD (ORIG CARD), VERIFIED LOADED PROPER SOFTWARE MM, NO ELMS STATUS MSG.