As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STATION 1701 THRU 1720 HAS SURFACE CORROSION IN 2 PLACES. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION 2 AREAS FOUND TO BE OUT OF LIMITS STA 1704.5 AND 1708.5 RBL 50. PERFORMED HFEC OF FASTENER HOLES AND DECK PLATE NO DEFECTS NOTED. FABRICATED AND INSTALLED DOUBLER PER EA PD57-53-007.