What was found
EMERGENCY EVAC HORN SOUNDS CONTINUOUSLY. COCKPIT HORN AFFECTED ONLY. CONFIRMED THAT CIDS DIRECTOR 2 WAS CAUSING THE FAULT. COMPLIED WITH DIRECTIVES, REINSTALLED GROUND WIRE 5037 AWM. REPLACED AND TESTED CIDS NR 2 PER MM. TESTED EVAC SYS PER MM. TESTS AND INDICATIONS ALL NORMAL.