What was found
COCKPIT AIR COND DUCT TEMP EXCEEDED 100 DEGREES SEVERAL TIMES DURING THE FLIGHT. FOUND FLIGHT DECK TEMP SENSOR SCREEN CLOGGED, CLEANED SCREEN. PERFORMED BITE TEST, NO FAULTS NOTED ON TEMP CONTROLLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
COCKPIT AIR COND DUCT TEMP EXCEEDED 100 DEGREES SEVERAL TIMES DURING THE FLIGHT. FOUND FLIGHT DECK TEMP SENSOR SCREEN CLOGGED, CLEANED SCREEN. PERFORMED BITE TEST, NO FAULTS NOTED ON TEMP CONTROLLER.