As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GROUND CREW REPORTS SCRAPE ON FUSELAGE UNDER AFT CARGO PIT DOOR. SAMC TEXT: DENT MEASURES .25 BY .25 AND IS .03125 DEEP. THE DENT IS 6.5 INCHES FROM THE DOOR CUT OUT AND 1.750 INCHES FROM A SKIN LAP. AREA LOWER OF FWD CARGO DOOR. BLENDED AREA SKIN REF SRM. WITININ LIMITS PG 101, AREA A. AREA WAS A GOUGE NOT A DENT. 2 INCHES LENGTH DEPTH .010. PRIMERED AREA WILL NEED PAINT.