What was found
LEFT L/E HALF MOON PANEL & SLAT WEDGE PANEL JUST ABOVE ARE DAMAGED WITH HALF MOON PANEL HAVING SECTION MISSING. LEFT NR 6 LEADING EDGE SLAT HAS DAMAGE. ACCOMPLISHED VISUAL INSPECTION OF ADJACENT AREA AND ASSURE NO FURTHER DAMAGE TO SLAT OR WING PANEL. APPLIED 2 LAYERS OF SPEED TAPE TO UNDERWING PANEL WITH 4 INCH OVERLAP TO SECURE. ONE LAYER OF SPEED TAPE TO SLAT WITH 4 INCH EXTENSION BEYOND DAMAGED AREA. ACCOMPLISHED AS STATED ABOVE.