What was found
DURING ACFT LOADING HAD IMPACT AT DOOR 2L. STATION IS 46 BETWEEN 1540 TO 1562 AND STRINGER LOC IS APPROX S22 TO S23. DIMENSIONS OF THE DENT ARE (INCHES): LENGTH 3.5 WIDTH 2.75 AND DEPTH 0.0858. THE DENT IS SMOOTH WITH NO SHARP EDGES CUTS OR CREASE, ADJACENT RIVETS APPEARS OK IAW SRM DENT IS WITHIN LIMITS. YELLOW DOT APPLIED. DENT IS JUST AFT AND BELOW DOOR 2LT CUTOUT NEAR REGISTRATION NUMBER. MARKED WITH YELLOW DOT.