CORROSION ON FLOOR BEAM AT STATION 365 RBL 60. MAJOR REPAIR. AFTER BLENDING CORROSION FOUND FLOORBEAM TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGE IAW SRM, FABRICATED REPAIR PART ANGLES. FABRICATED STRAP & BEAM. INSTALLED ALL PARTS IAW SRM 53-00-51.