What was found
APU AUTO SHUTDOWN THREE TIMES. APU INOP GENERATOR FILTER FAULT. REPLACED LUBE AND GENERATOR SCAVENGE OIL FILTER PER MM. ALSO SERVICED OIL, ADDED 1 QT. RAN APU AND LEAK CHECKED FILTER, NO LEAKS NOTED. RAN APU FOR 45 MIN. APU DID NOT AUTO SHUTDOWN.