What was found
CABIN INTERIOR FLOOR STRUCTURE AT CREASE BEAM STA 430 LEFT SIDE CORRODED. MAJOR REPAIR ACCOMPLISHED: REPLACED LT CREASE BEAM SECTION FROM STA 420 TO STA 440, PER 51-40-05, SRM 51-40-08 & DWG 140N0504.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN INTERIOR FLOOR STRUCTURE AT CREASE BEAM STA 430 LEFT SIDE CORRODED. MAJOR REPAIR ACCOMPLISHED: REPLACED LT CREASE BEAM SECTION FROM STA 420 TO STA 440, PER 51-40-05, SRM 51-40-08 & DWG 140N0504.