Service difficulty report · Sensor · Boeing 757222

Difficulty date
August 27, 2011
Submitted
September 22, 2011
Operation
Air carrier
Aircraft
N584UA
Make and model
Boeing 757222
Aircraft serial
26706
Aircraft time
60,331 hours, 21,109 cycles
Engine
Pwa PW2037
Part
Sensor
Condition
Faulty
Location
Ac Pack
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COCKPIT TEMP UNCONTROLLABLY HOT IN ALL MODES. USE STBY PLZ. GRN CHECK OK STBY. AUTO INOP. OK GRN CHECKS OK BOTH MODES. RDF-T :ZONE PACK & STBY CONTROLLERS ALL BITE TEST OK. REPLACED FLT DECK DUCT TEMP SENSOR TS175 PER MM AND REPLACED FLIGHT DECK ZONE TEMP SENSOR FILTER, BOTH NO HELP. WILL NEED TO CONTINUE TROUBLESHOOTING PER MM. RAN BOTH PACKS FOR 10 MIN. MOVED TEMP CONTROL KNOBS FULL COLD TO HOT AND BACK. FLT DECK AT .01 AND NEVER MOVED. REPLACED LT PACK CONTROLLER, PACK CTRL VALVE, L PACK 2 TEMP SENSOR, L PACK COMP OUTLET 2 TEMP SENSOR. ALL NO HELP. PACK OUT TEMP STILL SHOWS 50 DEGREES. REPLACED PACK TEMP SENSOR AS SUGGESTED BY AMM PG 130 FOR OUT OF CALIBRATION. RAN PACK IN AUTO FOUND PACK WOULD COOL AND ABLE TO VARY COCKPIT TEMP AS DEMANDED WITH TEMP KNOB.