What was found
DAMAGE FOUND LT SIDE OF FUSELAGE FWD OF DOOR 2L. APPROX STA 636 BELOW FLOOR LEVEL STRINGER S-17 DAMAGE APPROX 1.4375 X 0.875 PUNCTURE THRU SKIN. ACP INSPECTION OF SURROUNDING AREA INSIDE AND OUT, NO FURTHER DAMAGE NOTED. INSTALLED INTERIM RPR WITH ALUMINUM FOIL TAPE PER SAMC DIRECTION FOR THE PURPOSES OF NON-PRESSURIZED FERRY FLT. ACCMPL'D FUSELAGE REPAIR AT BS 636 BELOW STR 17L PER SRM 53-00- REPAIR 3. THE DAMAGE CUTOUT AREA IS WITHIN 20 INCHES OF AN EXISITING DOUBLER AND THE REQUIRED REPAIR DOUBLER THICKNESS WILL EXCEED THE MAXIMUM ALLOWABLE THICKNESS FOR A CAT 'B' REPAIR PER SRM REPAIR 3. REPAIR ACP PER UA EVA 81295.