As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM AT BS 365 CORRODED AT BL 0. MAJOR REPAIR ACCOMPLISHED. DEFECT TEXT SHOULD READ FLOOR SUPPORT AT BS 365 AT BL 0 CORRODED . REMOVED CORROSION & FOUND MATERIAL LOSS OUT OF LIMITS. REPLACED FLOOR SUPPORT P/N 141N5191-1 FROM BS 324-430 AT BL 0.