As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND ON CREASE BEAM AT BS 996 AT STRINGER S-17R. REMOVED CORROSION & FOUND BLEND OUT OF SRM LIMITS. ACCOMPLISH NDT INSPECTION OF BLENDED OUT AREA IN ADDITION TO NDT OF OPEN HOLES COMMON TO REPAIR AREA. NO DEFECTS FOUND. FABRICATED AND INSTALLED REPAIR ANGLE, FILLER & SHIM PER EA PD57-53-207. MAJOR REPAIR.