As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ACFT RETURNED TO GATE AFTER TAKE OFF ABORT AT 60 KTS FOR A GENERATOR FAULT. MTC MSG:24-31632. R-ENG IDG DISCONNECTED PER MEL. ALSO VISUAL INSPECTED REJECT TAKE OFF CONDITION PER MM. NO ABNORMAL CONDITION FOUND. REPLACED RT ENG IDG & ENG RUN TEST CHECK IDG WORKS NORMAL, LEAK CHECK OKAY, MSG CLEARED.