As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT AND RIGHT AILERON LEAKING HYDRAULIC FLUID. EVIDENCE OF LEAKAGE NOTED AT BOTH LT & RT AILERON AREA. OPERATED SURFACES, UNABLE TO IDENTIFY SUSPECT UNIT. RECHECK BOTH LT AND RT AILERONS WITHIN 75 FLT HOURS. HYD QUANTITY NORMAL WITH NO HISTORY OF HYD SERVICING. QTY LT 1.12, CTR .94, RT .96.