What was found
CREW REPORTED AT ROTATION, ACFT ENCOUNTERED NOTICEABLE BUMP IN RUNWAY SURFACE, IMMEDIATELY FOLLOWED BY AN AIR DEMAND PUMP AND NR 2 CTR SYS ACMP LOW PRESSURE LIGHTS. ADP LOW PRESSURE LIGHT EXTINGUISHED AFTER GEAR RETRACTED AND NR 2 ACMP LOW PRESSURE LIGHT EXTINGUISHED AFTER POWER REDUCTION. ALL LOW PRESSURE LIGHTS REMAINED OUT, GEAR & FLAP OPERATION SLOW. CTR QTY NORMAL, NO CONTROL ISSUES.