What was found
ACCOMPLISHED NR 1 ENG BOROSCOPE OF HPT BLADES, FOUND 1ST STAGE HPT BLADES WITH MATERIAL BREAK THROUGH INTO INTERNAL CAVITY CONCAVE SIDE AREA 'B' APPROX .273 SQ IN EXCEEDING LIMITS OF .0125 SQ IN PER MM. REPLACED ENGINE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACCOMPLISHED NR 1 ENG BOROSCOPE OF HPT BLADES, FOUND 1ST STAGE HPT BLADES WITH MATERIAL BREAK THROUGH INTO INTERNAL CAVITY CONCAVE SIDE AREA 'B' APPROX .273 SQ IN EXCEEDING LIMITS OF .0125 SQ IN PER MM. REPLACED ENGINE.