What was found
LIGHTNING STRIKES TO A/C. LIGHTING STRIKE DAMAGE. 3 FASTNERS IN A ROW DAMAGED AND OUT OF LIMITS PER SRM. SMC 44, SMC 44 AND SMC 45. NO RESTRICTIONS, LINE CREW OKAY. ACCOMPLISHED INSPECTION NO DISCREPANCIES NOTED. IN REFERENCE TO LIGHTNING STRIKE FORWARD OF LEFT WING, APPROX 18 RIVETS HAVE BEEN REWORKED AND PRIMED AND PAINTED. TOOK CORRECTIVE ACTION ON LIGHTNING STRIKE AT BS 533 & STR 27L, BS 538 & STR 27L, BS 540 AND STR 27L, BS 722 AND STR 25L, BS 528 AND 2" ABOVE STR 28L, BS 544 AND 2" ABOVE STR 28L, BS 709 AND 4" ABOVE STR 25L, BS 676 AND 5" ABOVE STR 26L, BS 669 AND 2" ABOVE STR 26L, BS 671 AND 2" ABOVE STR 26L, BS 524 AND 2" ABOVE STR 28L, BS 571 AND 6" ABOVE STR 27L, BS 524 AND 2" ABOVE STR 28L, BS 544 AND 2" ABOVE STR 28L. FASTENER TO BE INSPECTED EVERY 1000C AND BLIND FASTENER TO BE REPLACED BEFORE 16000C MF8275 CREATED TO MONITOR LIGHTNING STRIKE DAMAGE TO SKIN AT STA 709 AND 4" ABOVE STR 25. DRILLED OUT DAMAGE TO SKIN, INSP ACCOMPLISHED NDT OF HOLE, INSTALLED BLIND FASTENER. FASTENER TO BE REPLACED BEFORE 16000C MF8276 CREATED TO MONITOR