What was found
REF DAMAGED BULKHEAD CONNECTOR, SMC7. IPC SHOWS A DOTTED CUTOUT OF STRUCTURE FOR ATTACHMENT OF CONNECTOR. ITEMS 135 AND 120 ARE USED TO SECURE CONNECTOR. THE STRUCTURE IS WORN AWAY. THERE IS NOTHING TO ATTACH TO. REMOVED 1 EA FWD HI-LOKS IN FUEL TANK. PRE-DRILLED 2 OTHERS. REMAINING FASTENERS REMOVED, PANEL DRILLED, MODIFIED, ALODINED AND PRIMED. NEEDS SEALED AND INSTALLED. ALL HOLES ARE NOMINAL SIZE. STARTED TO INSTALL RPR PLATE. INSTALLED 4 FWD HILOKS IN WING TANK. COMPLETED INSTALL OF NEW PLATE, INSTALLED REMAINING HILOCS, QUARTER AND SIXES, INSTALLED HYD FITTINGS AND HOSES NO LEAKS.