What was found
AFT DECK AREA AT STA 1681 FLOORBEAM AT RBL 32 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF LIMITS OF SRM. CUT OUT DAMAGED AREA & ACP NDT OF OF OPEN HOLES COMMON TO REPAIR AREA FOR CRACKS. NONE FOUND. ACP INSURANCE CUT. FABRICATED & INSTALLED TWO REPAIR ANGLES, A STRAP & FILLER REPAIR PER EA PD57-53-227.