What was found
NR 1 ENG FUEL VAPOR FROM TAIL PIPE ON SHUT DOWN. REPLACED LT ENG FUEL CUT OFF SWITCHES AND PLUGS D109J AND D110J PER MM. ACCOMPLISHED TWO STOP STARTS PER JHR, FUEL FLOW 0 WHEN PUT INTO CUTOFF.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 ENG FUEL VAPOR FROM TAIL PIPE ON SHUT DOWN. REPLACED LT ENG FUEL CUT OFF SWITCHES AND PLUGS D109J AND D110J PER MM. ACCOMPLISHED TWO STOP STARTS PER JHR, FUEL FLOW 0 WHEN PUT INTO CUTOFF.