What was found
FUSELAGE DAMAGED 4FT BELOW F/O'S NR 2 WINDOW, INLINE WITH WINDOW AND AOA SENSOR. DENT IS 2.5 INCHES LONG AXIS AND .125" IN DEPTH. CTR HAS CREASE OR GOUGE. DAMAGE IS APPROX STA 297 BETWEEN RT STRINGER 14 & S14-D WITH NO FRAME CONTACT. CUT OUT DAMAGE TO 1 INCH FOR PREPARATION FOR SRM 53-00-01 REPAIR 7. CONT OF AMIS ITEM 2382014 :ACP HFEC FOR DAMAGE REMOVAL. VERIFIED ALL DAMAGE REMOVED. REPAIRED PER SRM 53-00-01 REPAIR 7 TIME LIMITED EXTERNAL REPAIR REQUIRES RECHECK AT 1000 CYCLES AND REPLACEMENT AT 6000 CYCLES REPAIRED IAW 747EN- 53-0367." HFEC, NO CRACK. MFG AND INSTALLED REPAIR.