Service difficulty report · Relay · Boeing 777222

Difficulty date
December 13, 2011
Submitted
January 13, 2012
Operation
Air carrier
Aircraft
N210UA
Make and model
Boeing 777222
Aircraft serial
30216
Aircraft time
42,265 hours, 9,251 cycles
Engine
Pwa PW4077
Part
Relay
Condition
Faulty
Location
Dc Power System
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DC POWER WILL NOT ENERGIZE WHEN BATTERY SWITCH PUSHED IN. RELAY K24006 & K24025 REPLACED AT P310 POWER MANAGEMENT PANEL, NO HELP. NOTE, GROUND POWER ENERGIZED & BATTERY SWITCH ON, DC POWER ENERGIZED, DE-ENERGIZED GROUND POWER , DC POWER STAY ON. BATTERY SWITCH OFF, DC POWER DE-ENERGIZED & PUSH BATTERY SWITCH ON, NO DC POWER. NO APU FIRE TEST OR UNABLE TO START APU. REPLACED DIODE BLOCK TB404 18F,D,B REF WDM 24-09-26. ACCOMPLISHED MAIN BATTERY TEST REF MM 24-31-01 AND STANDBY SYSTEM TEST, ALL NORMAL.