What was found
FUSE DENT 4 FEET BELOW F/O'S NR 2 WINDOW, INLINE WITH WINDOW AND AOA SENSOR. APPROX STA 297 BETWEEN S14 & S14D. REF PTT SEQ 0802018. REPAIRED IAW AMECO 747EN-53-0367. PER EVA 81484, INSP SKIN AROUND FIRST ROW OF FASTENERS ALONG EDGE OF DOUBLER AS SHOWN IN SRM 53-00-01 REPAIR 1 DETAIL III AT 6000 FC WITH INT HFEC OR AT 1500 FC WITH EXT LFEC. INSP THRESHOLD 24543 PTC. ONCE EC IS PUBLISHED, CF CAN BE CLEARED. REF: TABLE IV OF SRM.