What was found
DENT ON RT FUSELAGE STA1740 JUST ABOVE AFT CARGO DOOR. DENT IS OUTSIDE OF SRM 53-00-01 FIGURE 101 ALLOWABLE LIMITS. OK FOR FERRY FLIGHT WITH LIMITED MAX CABIN PRESS DIFFERENTIAL OF 6.0 PSI. TOMC DENT IS OUTSIDE OF SRM 53-00-01 FIGURE 101 ALLOWABLE LIMITS. THE REPAIR ACCOMPLISHED TO DENT AT STA 1740 NEAR AFT CARGO DOOR UPPER HINGE WAS DONE IN ACCORDANCE WITH AVO1139 REF SEQ 0832011. DAMAGED REPAIRED IAW ECRA5330-04197 ON NONROUTINE 50002 PER ECRA.