What was found
DENT REPORTED ON LT FUSELAGE FORWARD OF DOOR 2L. DENT AT BS 620 STR 15L AND MEASURES 1 X 1 X .09 OPBLM. ACP EDDY CURRENT, NO CRACK PERFORMED INTERIM REPAIR PER ECRA 5330-04 194 PART 1 OK TO CONTINUE AND PERMANENT REPAIR OF THE FUSELAGE SKIN AND STRINGER AS REQUIRED WITHIN 5 CYCLES MARKED WITH DOT. RE-INSPECTION REQUIRED BY QC AT THE FIRST MAINTENANCE OPPORTUNITY WHERE GROUND TIME ALLOWS. BACK DRILLING DOUBLER AND TRIPLER. -RPR- :ACCOMPLISHED REPAIR PER ECRA: 5330-04199.