What was found
LEFT ENGINE FIRST START ABORTED, SECOND START OKAY. MAINT MSG IS 74-61501 'IGNITION SYSTEM NR 2 (L ENG) FAILED TO LIGHT ENGINE' REF FIM 74- 11 TASK 816. ECM DATA SHOWS LIGHT OFF TIMES SLOWER SINCE IGN2 (LOWER) EXCITER AND CABLE WERE PREV RPL 08DEC. IF FIM FINDS NO CAUSE OF POOR LIGHT OFF, RECOMMEND RPL EXCITER AND CABLE AGAIN. RPL'D :NO DEFECT FOUND PER FIM 74-11 TASK 816. RPL'D EXCITER, LEAD ASSY & PLUG PER MM 74-11-01, MM74-21-01 & MM74-21-02, AUDIBLE MAT TEST PASS.