What was found
UPPER DECK FLOORBEAM STA 1020 LBL 6 UPPER T-CHORD CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED CORRODED SECTION OF T-CAP. SPLICED IN NEW SECTION PER SRM 53-10-07, FAA FORM 8100 -9, & ECRA 5310-05444. EVERY 3,000 CYCLES PERFORM DETAILED VISUAL INSP OF REPAIR AREA. AT EVERY 6,000 CYCLES PERFORM HFEC INSP OF REPAIR AREA. INITIAL RE-INSPECTIONS TO BEGIN AT PTC 20,000. CURRENT PTC IS 8591.^13FEB OPB INF- :MF8649 CREATED TO RE-CHECK EVERY 3000 CYCLES.