What was found
FOUND INTERMITTENT SHORT IN P105 INTERGRATION PANEL BETWEEN CONN D4828J PIN B14 AND D4967J PIN A2. FAULT WAS AT D4828J WHEN PLUG WAS CONNECTED. CLEANED RECEPTACLE AND SHORT WENT AWAY. CK'D INTEGRITY OF PIN AND SOCKET FOR RETENTION AND FOUND TO BE OK. CK'D FOR SHORTS WITH MEGGER WHILE MOVING CONNECTOR AND FAULT DID NOT RETURN. EEC PWR CK'S NORMAL WITH START SELECTOR 26592EEC MAINT SWITCH AND FUEL SHUTOFF LEVER.