UNABLE TO CONTROL FLT DECK TEMP DURING DESCENT TEMP GOT DOWN TO 65F. FLT DCK TEMP TOO COLD. FOUND COCKPIT DUCTING CLOGGED. REMOVED DEBRIS AND REPLACED LT PACK TEMP SENSOR AND RT PACK FLOW CONTROL VALVE.