What was found
RIGHT ELEVATOR POSITION INDICATION INOP DURING FLT CONTROL CHECK. ALL 3 HYD SYSTEMS PRESSURIZED. CYCLE FCC AC CB'S, NO HELP. SWITCHED EICAS COMPUTER FROM LEFT, RIGHT AND BACK TO AUTO, NO HELP. VERIFIED OPERATION 908-12. RPL'D LEFT EICAS COMPUTER PER MM, CHECKED WIRES TO XMITTR. NO INDICATION PROBLEMS, SYSTEM OPS NORMAL.