What was found
INTERCOSTAL IN AREA OF DAMAGE IS DENTED. REMOVED DAMAGE INTERCOSTAL. REPLACEMENT PART ON ORDER. PER ENGINEERING REMOVED 5 FASTENERS AND MAPPED OUT DAMAGE AREA FOR SKIN THICKNESS CHECK. ACCMP'D THICKNESS INSP OF BLENDED AREA, FOUND THICKNESS BLEND TO BE .046 INCH OR 23% OTHERS WERE .016, .002 AND .002. COMPLETED BLENDING OF 4 AREAS. CURRENT PTT 81,389.24 GOUGE AT RT FUSELAGE BS 1373. GOUGE WORKED AS PER EC-RA#5330-04217. OK TO CONTINUE IN SERVICE FOR 50 FLYING HOURS MAX. ACCMP'D PERMANENT REPAIR PER ECRA 5330-04217.