What was found
FUSELAGE DENTED AT BS 395 BETWEEN STRINGERS 35-36L. EVALUATED DENT & FOUND OUT OF LIMITS. CUT-OUT DAMAGE & ACCOMPLISHED NDT FOR CRACKS. NONE FOUND. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLER REPAIR REF SRM. MAJOR REPAIR
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.