What was found
FUSELAGE DENT BS 610, S16L. CUT OUT DAMAGED SECTION OF SKIN, ACCOMPLISHED HFEC OF CUT OUT NO CRACKS NOTED. FABRICATED AND INSTALLED FILLER AND DOUBLER PER SRM 53-00-01 REPAIR 2 ON NR 4619N00753. MAJOR REPAIR
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE DENT BS 610, S16L. CUT OUT DAMAGED SECTION OF SKIN, ACCOMPLISHED HFEC OF CUT OUT NO CRACKS NOTED. FABRICATED AND INSTALLED FILLER AND DOUBLER PER SRM 53-00-01 REPAIR 2 ON NR 4619N00753. MAJOR REPAIR