As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT BELLY FAIRING SUPPORT BRACKET UPPER ANGLE HAS .5 INCH CRACK AT FRAME 46 BELOW KEEL BEAM. VIEW FROM AFT SIDE OF WHEEL WELL WITH PANEL 147EB REMOVED. VERIFIED WITH HFEC, CRACK TO BE 1 INCH LONG. MAX LIMIT IS 4.5 INCH. NEEDS VISUAL REINSPECT EVERY 500 CYCLES TO MONITOR FOR PROGRESSION UNTIL COA 406531 OR PERM REPAIR IS ACP PER SRM 53-35-11-201 FIG 229. SFOIQ WOODHOUSE TRIMMED DRILLED AND DEBURRED REPAIR ANGLE IAW SRM. INSTALLED REPAIR ANGLE IAW SRM. PERFORMED LEAK CHECKS ON DISTURBED HYD LINES.