As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DENT ON FUSELAGE AT BS 331 STRINGER S30L FOUND OUT OF SRM LIMITS. TRIMMED OUT DAMAGE IAW EA PT67-53-005 AND ECRA 5310-05483. ACCOMPLISHED NDT. NO CRACKS FOUND. ACCOMPLISHED INSURANCE CUT PER EA FABRICATED AND INSTALLED EXTERNAL DOUBLER AND FILLER REPAIR REF EA AND ECRA.