What was found
STRINGER 11 LEFT AT FR 59-60 HAS CORROSION, AFT CARGO BAY. INSTALLED NEW STRINGER PER SRM 51-44-11, AND 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 11 LEFT AT FR 59-60 HAS CORROSION, AFT CARGO BAY. INSTALLED NEW STRINGER PER SRM 51-44-11, AND 51-42-11.