What was found
FLOORBEAM TEE CORRODED BEYOND SRM LIMITS AT BS 1640, BL 0 TO RBL 5. REMOVED DAMAGED TEE, FABRICATED A NEW TEE SECTION, REPAIR ANGLES AND STRAPS AND INSTALLED PER SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM TEE CORRODED BEYOND SRM LIMITS AT BS 1640, BL 0 TO RBL 5. REMOVED DAMAGED TEE, FABRICATED A NEW TEE SECTION, REPAIR ANGLES AND STRAPS AND INSTALLED PER SRM 53-00-51.