As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CIRCUIT BREAKER C-14 ON P6-3 PANEL, LABELED "115 VAC BUS L SECT 2", TOP IS SHEARED OFF. MAINT TEXT: CORRECTION: SHOULD READ "SECT 1". REPLACED CIRCUIT BREAKER C313 (WDM 24-51-11). OPERATIONAL TEST OF P11-3 POWER MM TASK 24-50-00-715-003, EICAS DISPLAYS AND LIGHTING FUNCTIONS OK.