What was found
APU BLEED AIR ONLY 8PSI , UNABLE TO START EITHER ENGINE. REPLACED APU SURGE CONTROL VALVE AND AIR SUPPLY SHUTOFF VALVE. APU BLEED PSI NORMAL WITH BOTH PACKS ON AND CTR ADP ON, APU BLEED PSI NORMAL DURING ENGINE DRY MOTOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU BLEED AIR ONLY 8PSI , UNABLE TO START EITHER ENGINE. REPLACED APU SURGE CONTROL VALVE AND AIR SUPPLY SHUTOFF VALVE. APU BLEED PSI NORMAL WITH BOTH PACKS ON AND CTR ADP ON, APU BLEED PSI NORMAL DURING ENGINE DRY MOTOR.