What was found
'R PACK INOP' LIGHT ON. EICAS MSG 'R PACK TEMP' DISPLAYED. REPLACED APU SURGE CONTROL VALVE AND AIR SUPPLY SHUTOFF VALVE. APU BLEED PSI NORMAL WITH BOTH PACKS ON AND CTR ADP ON, APU BLEED PSI NORMAL DURING ENGINE DRY MOTOR. APU AIR SUPPLY SHUTOFF VALVE REPLACED, REF DF511, NOW RT PACK OPERATION NORMAL IN AUTO MODE AND R PACK INOP LIGHT NOT ON AND NO STATUS MESSAGES.