As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXTERIOR FUSELAGE BLENDED AREA OUT OF LIMITS AT BS 448-458 STR 22-23L. CUTOUT DAMAGE AREA OUT IAW SRM 53-00-01. PERFORMED HFEC SURFACE AREA IAW NDT MAN UAL PER PART 6 51-00-19. FABRICATED DOUBLER IAW 53-00-01. DRILLED DOUBLER IAW SRM 51-40-05. INSTALLED DOUBLER IAW SRM 51-40-02.