What was found
RECEIVED A RIGHT GENERATOR OFF. CYCLED THE GENERATOR CONTROL SWITCH AND THE RIGHT GENERATOR RECOVERED MOMENTARILY THEN WENT OFF AGAIN. RAN ENGINE. GENERATOR WENT OFFLINE. REPLACED RT IDG PER MM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RECEIVED A RIGHT GENERATOR OFF. CYCLED THE GENERATOR CONTROL SWITCH AND THE RIGHT GENERATOR RECOVERED MOMENTARILY THEN WENT OFF AGAIN. RAN ENGINE. GENERATOR WENT OFFLINE. REPLACED RT IDG PER MM.