As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DAMAGE TO RIGHT I/B FLAP AFT I/B TRAILING EDGE WEDGE. MEASURES APPROX 8IN BY 3IN. WILL REQUIRE PERM REPAIR PER SRM. MATERIAL ETA 0730 UNDER OSTF'S LISTED. REPAIRED DAMAGED FLAP PER SRM 57-53-01 & SRM 51-70-17. PRIMED & PAINTED TO MATCH.