What was found
RAMP REPORTS DENT AT LEFT FUSE AT STA 755 BET STR 15L + 16L. AFT OF DOOR 2L. MEASUREMENTS ARE 1.5\ WIDTH X 1.75\ LENGTH, .070\ DEEP. A-Y=21.4 CONT OF AMIS ITEM 0672022. ACP A INTERIM REPAIR BURNISH OUT ALL SHARP EDGES AND DENT IS SMOOTH AND FREE FROM SHARP CREASES GOUGES AND CRACK. ACP A NTM PART 6-51-00-19. APPLIED PRIMER, ALODINE AND PAINT AN EXAMINATION OF THE DENT IS REQUIRED EVERY 300 HOURS AND A PERMANENT REPAIR IS MADE AT OR BEFORE THE NEXT C CHECK.