As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO DOOR FWD LOWER CORNER HAS 6 EA DENTS 1" TO 5.5" FROM FWD EDGE, 1.5" TO 6.25" FROM BOTTOM EDGE. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 52-30-01, DET VI NOTE J. REPAIRED IAW SRM 52-30 -01, FIG 201. THIS REPAIR IS CATEGORY A.